Current Transformer

By Frank Baker, Technical Editor


Current Transformer

Substation Maintenance Training

Our customized live online or in‑person group training can be delivered to your staff at your location.

  • Live Online
  • 12 hours Instructor-led
  • Group Training Available
Regular Price:
$699
Coupon Price:
$599
Reserve Your Seat Today

Download Our OSHA 3875 Fact Sheet – Electrical PPE for Power Industry Workers

  • Follow rules for rubber gloves, arc-rated PPE, and inspection procedures
  • Learn employer obligations for testing, certification, and training
  • Protect workers from arc flash and electrical shock injuries

A current transformer converts high electrical current into safe, measurable values for meters and protective relays, enabling accurate monitoring, control, and fault detection in industrial, commercial, and utility power systems.

A current transformer is a measurement and protection device used in electrical power systems to safely reproduce high primary current at a standardized secondary level for meters, relays, and monitoring equipment. This allows electrical current flowing through the primary winding to be observed, analyzed, and controlled without exposing instruments or personnel to dangerous current levels.

Unlike voltage transformers, which reduce voltage magnitude, current transformers are designed to reduce high current levels while accurately replicating current behavior under both normal and fault conditions. They are primarily used for measuring alternating current AC in power systems, making them essential components in substations, switchgear, industrial facilities, and utility distribution networks.

This guide presents the transformer CT as a system category device rather than only a definition. It explains its role in power systems, structural types, accuracy and burden considerations, saturation behavior, installation practices, selection criteria, and specialized applications, while directing readers to more detailed technical pages.

 

Role of the Current Transformer in Power Systems

Current transformers enable high-current electrical systems to be observed and controlled. Without CTs, it would be impractical and unsafe to connect measuring instruments or protective relays directly to high-current conductors.

The primary conductor either passes through the CT core or forms part of the transformer structure, depending on design. Current flowing through the primary winding creates a magnetic field that induces a proportional current in the secondary winding.

Sign Up for Electricity Forum’s Electrical Transformers Newsletter

Stay informed with our FREE Electrical Transformers Newsletter — get the latest news, breakthrough technologies, and expert insights, delivered straight to your inbox.

By reproducing primary current in a controlled secondary circuit, a current transformer enables:

  • Accurate energy metering

  • Protective relay operation

  • System monitoring and diagnostics

  • Load analysis and control

Protective relays supplied by CTs commonly trip a circuit breaker when fault current exceeds safe limits.

Their performance directly affects billing accuracy, fault detection reliability, and overall system protection.

Electrical Transformer Maintenance Training

Substation Maintenance Training

Request a Free Training Quotation

 

Metering and Protection Functions

Current transformers serve two primary functions in the system.

Metering CTs provide precise current values for energy measurement, power quality monitoring, and operational analysis. Accuracy is prioritized under normal operating conditions.

Protection CTs supply current signals to protective relays that detect abnormal conditions such as short circuits, ground faults, and overloads. These CTs must maintain accuracy under fault currents and transient conditions.

While both types measure current, they are designed differently and must be selected based on their intended role.

 

Major Current Transformer Types

Current transformers are manufactured in several structural forms to suit different installation environments and system requirements.

Wound type CTs: use a primary winding connected in series with the circuit and are used where high accuracy is required.

Bar type current transformers:  use a solid primary bar as the conductor and are common in high-current switchgear assemblies.

Window or toroidal CTs: allow the primary conductor to pass through the core and are widely used in distribution and protection systems.

Split core current transformers: open mechanically to allow installation without disconnecting conductors and are commonly used for retrofit and temporary measurements.

Each type has different accuracy behavior, burden tolerance, and installation constraints.

For temporary and field applications, see the dedicated portable current transformer page:
portable current transformer

 

Accuracy, Burden, and System Performance

A current transformer does not operate in isolation. Its performance depends on:

  • Primary current range

  • Secondary burden (connected load)

  • Core material and design

  • Accuracy class

  • System fault levels

If the burden exceeds design limits or the core saturates, measurement and protection accuracy deteriorate. This is why selecting a current transformer must be coordinated with the connected instruments and relays.

The relationship between primary and secondary current is explained in detail in the ratio guide:
current transformer ratio

 

CT Saturation and Its Consequences

Core saturation is one of the most important limitations of current transformers. When the magnetic core saturates, the secondary current no longer tracks the primary current accurately. This can result in:

  • Incorrect relay operation

  • Delayed fault clearing

  • Metering errors

  • Protection miscoordination

Saturation behavior depends on fault current magnitude, DC offset, burden, and core design. Protection CTs are designed with higher knee-point voltages to delay saturation under fault conditions.

 

Installation and Safety Principles

Current transformers must always be treated as live measurement devices.

The secondary circuit must never be left open while the primary is energized. An open secondary winding can develop dangerously high voltage, leading to insulation failure or personal injury.

Secondary circuits must always be shorted before disconnecting instruments. Proper grounding practices must be followed to prevent hazardous potentials from developing.

These practices are universal across all current transformer types and system voltages.

 

Current Transformers in Monitoring and Simulation

Modern power systems increasingly rely on digital modelling and analysis. Current transformer behavior under different system conditions can be studied using simulation tools to predict performance under load, fault, and transient conditions.

For modelling applications and training use, see: current transformer simulation

 

Specialized CT Applications

Certain current transformer designs serve specialized protection roles.

Test Your Knowledge About Electrical Transformers!

Think you know Electrical Transformers? Take our quick, interactive quiz and test your knowledge in minutes.

  • Instantly see your results and score
  • Identify strengths and areas for improvement
  • Challenge yourself on real-world electrical topics
Take Quiz

Core-balanced current transformers are used for residual-current and ground-fault detection by measuring the vector sum of the phase currents.

Their construction and application are covered separately to avoid confusion with standard measurement CTs:
what is core balance current transformer.

Large utility systems often use high-accuracy, high-stability current transformer designs optimized for protection and revenue metering in transmission environments: core current transformer

 

How to Select a Current Transformer

Proper current transformer selection requires evaluating:

  • Primary current rating

  • Fault current capability

  • Accuracy class

  • Burden compatibility

  • Application type (metering or protection)

  • Mechanical configuration

  • Environmental conditions

Selection errors are a leading cause of protection malfunctions and metering disputes. Current transformer choice should always be coordinated with relay, meter, and system studies.

 

Why the Current Transformer Remains Critical

Despite advances in digital measurement technology, current transformers remain the primary interface between physical power systems and electronic protection and monitoring equipment.

Their reliability, simplicity, and passive operation make them indispensable in both traditional and modern power networks.

A properly selected and installed current transformer will operate accurately for decades, forming the foundation of safe, stable, and measurable electrical power systems.

 

Related Learning Paths

 

Download the 2026 Electrical Training Catalog

Explore 50+ live, expert-led electrical training courses –

  • Interactive
  • Flexible
  • CEU-cerified